Customization: | Available |
---|---|
Material: | Porcelain Clay |
Type: | Vitrified Tiles |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sequence | Test Item | Test Method | Provisions of Standard | Test Result |
1 | Dimensions | |||
Lengh and width | EN ISO 10545-2 |
The deviation, in percent, of the average size for each tiles (2 or 4 sides) from the work size: ± 0.6% | -0.03%~+0.05% | |
The deviation, in percent, of the average size for each tiles (2 or 4 sides) from the average size of the 10 test specimens (20 or 40 sides): ± 0.5% | -0.01%~+0.01% | |||
Thickness | EN ISO 10545-2 |
The deviation, in percent, of the average size for each tiles (2 or 4 sides) from the work size: ± 0.5% | -0.77%~+0.77% | |
2 | Physical properties | |||
Water Absorption | EN ISO 10545-3 |
Average: E ≤0.5%, Individual maximum 0.6% | Average: 0.10% Individual maximum: 0.12% |
|
Breaking strength | EN ISO 10545-4 |
Thickness ≥7.5mm, Not less than 1300N | 2394N | |
Modulus of rupture | EN ISO 10545-4 |
Miinimum 35MPa, Individual minimum 32MPa | Average: 49.2MPa minimun: 48.1MPa |
|
Resistance to deep abrasion of unglazed tiles | EN ISO 10545-6 |
Removed volume, in cubic millimeters, Maximum 175 | 95mm³ | |
Thermal shock resistance | EN ISO 10545-9 |
Test method available | Fully resistant | |
Frost resistance | EN ISO 10545-12 |
-5°C~+5°C,100 cycle no crack | Fully frose resistant | |
Slip resistance (Ramp Test) |
DIN 51130 | Manufacturer to state value and test method used | Mean overall acceptance angle: 45° | |
Slip resistance (Pendulum test) |
BS 7976-2 | Manufacturer to state value and test method used | Dry 55 Wet 13 |
|
3 | Chemical properties | |||
Resistance to chemicals | EN ISO 10545-13 |
Resistance to concentrations of acids and alkalis | Manufacturer to state classification |